IVP(Q)41
IVP(Q)41 DoublePumps Max. Continuous Pressures
| Model | Shaft end Pump (No.1 Outlet) | Cover end Pump (No.2 Outlet) | Max. Speed
rpm |
Min. Speed
rpm |
||||
|---|---|---|---|---|---|---|---|---|
| ♦Code | Geometric Displacement
cm3/r |
Max. Pressure
bar |
♦Code | Geometric Displacement
cm3/r |
Max. Pressure
bar |
|||
| IVP(Q)41 | 30 | 96.0 | ♣172
F3 = 69 F11 = 157 |
10 | 31.0 | ♣207
F3 = 69 F11 = 157 |
1800
F3 = 1200 F11 = 1500 |
600 |
| 35 | 109 | |||||||
| 11 | 35.0 | |||||||
| 38 | 128 | |||||||
| 42 | 134 | |||||||
| 12 | 37.9 | ♣157
F3 = 69 F11 = 138 |
||||||
| 50 | 156 | |||||||
| 60 | 189 | |||||||
| 67 | 210 | 14 | 44.2 | ♣138
F3 = 69 F11 = 138 |
||||
| 72 | 236 | |||||||
♦ Rated capacity in USgpm at 1200 rpm and 6.9 bar.
♣Transient (peak) pressure 10% over the max. continuous pressure rating for 0.5 seconds or less duration is allowed.
Dimensions
IVP41 Double Pumps: Flange Mounting

IVPQ41 Double Pumps: Flange Mounting

IVP(Q)41 Double Pumps: Foot Mounting

Assembly
IVP41 Double Pumps – Assembly

IVPQ41 Double Pumps – Assembly