IVP(Q)41      

PDF
IVP(Q)41

IVP(Q)41 DoublePumps Max. Continuous Pressures

Model Shaft end Pump (No.1 Outlet) Cover end Pump (No.2 Outlet) Max. Speed

rpm

Min. Speed

rpm

♦Code Geometric Displacement

cm3/r

Max. Pressure

bar

♦Code Geometric Displacement

cm3/r

Max. Pressure

bar

IVP(Q)41 30 96.0 ♣172

F3 = 69

F11 = 157

10 31.0 ♣207

F3 = 69

F11 = 157

1800

F3 = 1200

F11 = 1500

600
35 109
11 35.0
38 128
42 134
12 37.9 ♣157

F3 = 69

F11 = 138

50 156
60 189
67 210 14 44.2 ♣138

F3 = 69

F11 = 138

72 236

Rated capacity in USgpm at 1200 rpm and 6.9 bar.

♣Transient (peak) pressure 10% over the max. continuous pressure rating for 0.5 seconds or less duration is allowed.

Dimensions

IVP41 Double Pumps: Flange Mounting

IVP41 Flange Mounting: Dimensions

IVPQ41 Double Pumps: Flange Mounting

IVPQ41 Flange Mounting: Dimensions

IVP(Q)41 Double Pumps: Foot Mounting

IVPQ41 Foot Mounting: Dimensions


Assembly

IVP41 Double Pumps – Assembly

IVP Double Pumps: Assembly

IVPQ41 Double Pumps – Assembly

IVPQ Double Pumps: Assembly

PDF